| # Sensor Control Technical Specification | |
| # Overview | |
| This document specifies the functionality of the `sensor control` module. | |
| The `sensor control` module is a comportable front-end to the [analog sensor top](../ast/README.md). | |
| It provides basic alert functionality, pad debug hook ups, and a small amount of open source visible status readback. | |
| Long term, this is a module that can be absorbed directly into the `analog sensor top`. | |
| ## Features | |
| - Alert hand-shake with `analog sensor top` | |
| - Alert forwarding to `alert handler` | |
| - Status readback for `analog sensor top` | |
| - Pad debug hook up for `analog sensor top` | |
| - Wakeup based on alert events | |
| # Theory of Operations | |
| ## Block Diagram | |
| The diagram below shows how `sensor control` helps `analog sensor top` integration into the overall design. | |
| ## Recoverable and Fatal Alerts | |
| The `analog sensor top` sends alert requests in independent, differential form to the `sensor control`. | |
| Each alert request consists of a pair of signals, one active high and one active low. | |
| The active polarity of each signal is independent, due to the imprecise sensor timing that drives the alert. | |
| This means that the `sensor control` recognizes an active alert as long as one of the lines is active, and not the pair of signals being in a particular state. | |
| Each signal in the differential pair is thus a separate dedicated alert indicator. | |
| Once an alert request is detected as active, the `sensor control` formulates a proper alert event through the `prim_alert_sender` and sends a notification to the `alert handler`. | |
| The `sensor control` can optionally generate alert acknowledgements back to the `analog sensor top`. | |
| For each incoming alert, it can be programmed as fatal or recoverable through [`FATAL_ALERT_EN`](data/sensor_ctrl.hjson#fatal_alert_en). | |
| If set to recoverable, an alert will be registered in [`RECOV_ALERT`](data/sensor_ctrl.hjson#recov_alert) and the original `analog sensor top` event acknowledged. | |
| The acknowledgement prevents alerts from constantly being sent. | |
| If set to fatal, an alert will be registered in [`FATAL_ALERT`](data/sensor_ctrl.hjson#fatal_alert) but the original `analog sensor top` event will not be acknowledged. | |
| This causes the alert to constantly send until the system escalates in some form. | |
| ## Wakeup Requests | |
| In addition to forwarding events to the `alert handler`, incoming events can also be aggregated into a wakeup request to the system. | |
| The `sensor control` does not make assumptions about its power domains and thus it is up to the integrating system to decide which power modes allow alert event wakeups. | |
| As an example, if the `sensor control` is not placed in an always on domain, then it cannot send alert based wakeups if the system is in a deep low power state. | |
| It will only be able to send wakeups when the system is powered and the `clk_aon_i` input is available. | |
| ## Hardware Interfaces | |
| ### Signals | |
| * [Interface Tables](data/sensor_ctrl.hjson#interfaces) | |
| # Programmer's Guide | |
| Each available alert has a corresponding fatality configuration. | |
| If an alert event is set to 1 in [`FATAL_ALERT_EN`](data/sensor_ctrl.hjson#fatal_alert_en), `sensor control` treats it as a fatal event instead of a recoverable event. | |
| Fatal events are not acknowledged, and continuously send alert events in the system until some kind of escalation is seen. | |
| ## Device Interface Functions (DIFs) | |
| - [Device Interface Functions](../../../sw/device/lib/dif/dif_sensor_ctrl.h) | |
| ## Register Table | |