  "commit": "fb6017b3eff1e4bd62099c86a9fb846188da3b39",
  "tree": "6b663d4373fe1e4ccfbc9be5afab7c1c5a0d1a64",
  "parents": [
    "8e68fab824f031a4f325a0f38e5b409b0a8f11ab"
  ],
  "author": {
    "name": "Michael Hoang",
    "email": "hoangm@google.com",
    "time": "Thu Jun 29 19:48:12 2023 +0000"
  },
  "committer": {
    "name": "Michael Hoang",
    "email": "hoangm@google.com",
    "time": "Wed Jul 12 14:20:27 2023 +0000"
  },
  "message": "[smc/hw] Prevent LSU misalignment accesses on dPTW\n\n-DMEM PTWs on a misaligned load/store previously had the LSU fsm waiting\non rvalid in addition to the MMU\n\nChange-Id: Ib6601b3436d9d4d9bbcd8ae5ecbbc8ac089abf3c\n",
  "tree_diff": [
    {
      "type": "modify",
      "old_id": "0471728a42859e0b1e6c48997019ff26a135cb7f",
      "old_mode": 33188,
      "old_path": "hw/top_matcha/ip/smc/rtl/smc_core.sv",
      "new_id": "43e52424e46243984d50af1a609d71238edb2fd4",
      "new_mode": 33188,
      "new_path": "hw/top_matcha/ip/smc/rtl/smc_core.sv"
    },
    {
      "type": "modify",
      "old_id": "87249916b929fd7886ec2e335c1e660772e160ef",
      "old_mode": 33188,
      "old_path": "hw/top_matcha/ip/smc/rtl/smc_load_store_unit.sv",
      "new_id": "cac7e8992c34cea27a05d26e89673d2af6910113",
      "new_mode": 33188,
      "new_path": "hw/top_matcha/ip/smc/rtl/smc_load_store_unit.sv"
    }
  ]
}