*** Keywords ***
Prepare Machine
Execute Command include @scripts/single-node/ek-ra2e1.resc
*** Test Cases ***
Should Run Periodicaly Blink LED
Prepare Machine
Create Led Tester sysbus.port9.led_blue
Create Terminal Tester sysbus.segger_rtt
Execute Command agt0 IRQ AddStateChangedHook "Antmicro.Renode.Logging.Logger.Log(LogLevel.Error, 'AGT0 ' + str(state))"
# Timeout is only used for checking whether the IRQ has been handled
Create Log Tester 0.001
# Configuration is roughly in ms
Wait For Prompt On Uart One-shot mode:
Write Line To Uart 10 waitForEcho=false
Wait For Line On Uart Time period for one-shot mode timer: 10
Wait For Prompt On Uart Periodic mode:
Write Line To Uart 5 waitForEcho=false
Wait For Line On Uart Time period for periodic mode timer: 5
Wait For Prompt On Uart Enter any key to start or stop the timers
Write Line To Uart waitForEcho=false
# Timeout is extended by an additional 1ms to account for rounding errors
Wait For Log Entry AGT0 True level=Error pauseEmulation=true timeout=0.011
Wait For Log Entry AGT0 False level=Error pauseEmulation=true
# move to the begining of a True state
Assert Led State True timeout=0.01 pauseEmulation=true
# Run test for 5 cycles
Assert Led Is Blinking testDuration=0.05 onDuration=0.005 offDuration=0.005 tolerance=0.2 pauseEmulation=true
Assert Led State True timeout=0.005 pauseEmulation=true
# Stop timers, clear log tester history and check whether the periodic timer stops
Write Line To Uart waitForEcho=false
Wait For Line On Uart Periodic timer stopped. Enter any key to start timers. pauseEmulation=true
Assert And Hold Led State True 0.0 0.05