This document specifies RISC-V Timer hardware IP functionality. This module conforms to the Comportable guideline for peripheral functionality. See that document for integration overview within the broader top level system.
The timer module provides a configurable number of 64-bit counters where each counter increments by a step value whenever the prescaler times out. Each timer generates an interrupt if the counter reaches (or is above) a programmed value. The timer is intended to be used by the processors to check the current time relative to the reset or the system power-on.
In this version, the timer doesn't consider low-power modes and assumes the clock is neither turned off nor changed during runtime.
The timer IP provides memory-mapped registers mtime
and mtimecmp
which can be used as the machine-mode timer registers defined in the RISC-V privileged spec. Additional features such as prescaler, step, and a configurable number of timers and harts have been added.
The timer module is composed of tick generators, counters, and comparators. A tick generator creates a tick every time its internal counter hits the {{< regref “CFG0.prescaler” >}} value. The tick is used to increment mtime
by the {{< regref “CFG0.step” >}} value. The 64-bit mtime
value is compared with the 64-bit mtimecmp
. If mtime
is greater than or equal to mtimecmp
, the timer raises an interrupt.
{{< incGenFromIpDesc “../data/rv_timer.hjson” “hwcfg” >}}
The tick module inside the timer IP is used to generate a fixed period of pulse signal. This allows creation of a call-clock timer tick such as 1us or 10us regardless of the system clock period. It is useful if the system has more than one clock as a clock source. The firmware just needs to adjust the {{< regref “CFG0.prescaler” >}} value and the actual timer interrupt handling routine does not need a variable clock period to update mtimecmp
.
For instance, if a system switches between 48MHz and 200MHz clocks, a prescaler value of 47 for 48MHz and 199 for 200MHz will generate a 1us tick. In this version, the timer only supports a single fixed clock, so the firmware should change {{< regref “CFG0.prescaler” >}} appropriately.
The timer IP supports more than one HART and/or more than one timer per hart. Each hart has a set of tick generator and counter. It means the timer IP has the same number of prescalers, steps, and mtime
registers as the number of harts.
Each hart can have multiple sets of mtimecmp
, comparator logic, and expire interrupt signals. This version of the IP is fixed to have one Hart and one Timer per Hart.
Below is an example configuration file for N_TIMER
2 and N_HARTS
2. It has separate interrupts per timer and a set of interrupt enable and state registers per Hart.
{ // ... interrupt_list: [ { name: "timer_expired_hart0_timer0", desc: "raised if hart0's timer0 expired (mtimecmp >= mtime)" }, { name: "timer_expired_hart0_timer1", desc: "raised if hart0's timer1 expired (mtimecmp >= mtime)" }, { name: "timer_expired_hart1_timer0", desc: "raised if hart1's timer0 expired (mtimecmp >= mtime)" }, { name: "timer_expired_hart1_timer1", desc: "raised if hart1's timer1 expired (mtimecmp >= mtime)" }, ], //... registers: { // ... { skipto: "0x100" }, { name: "CFG0", desc: "Configuration for Hart 0", swaccess: "rw", hwaccess: "hro", fields: [ { bits: "11:0", name: "prescale", desc: "Prescaler to generate tick" }, { bits: "23:16", name: "step", resval: "0x1", desc: "Incremental value for each tick" }, ], }, // ... { multireg: { name: "INTR_ENABLE0", desc: "Interrupt Enable", count: 2, cname: "TIMER", swaccess: "rw", hwaccess: "hro", fields: [ { bits: "0", name: "IE", desc: "Interrupt Enable for timer" } ] } }, { multireg: { name: "INTR_STATE0", desc: "Interrupt Status", count: 2, cname: "TIMER", swaccess: "ro", hwaccess: "hrw", fields: [ { bits: "0", name: "IS", desc: "Interrupt status for timer" } ], } }, // ... { skipto: "0x200" }, { name: "CFG1", desc: "Configuration for Hart 1", swaccess: "rw", hwaccess: "hro", fields: [ { bits: "11:0", name: "prescale", desc: "Prescaler to generate tick" }, { bits: "23:16", name: "step", resval: "0x1", desc: "Incremental value for each tick" }, ], }, // ... { name: "TIMER_V_UPPER1", desc: "Timer value Upper", swaccess: "rw", hwaccess: "hrw", fields: [ { bits: "31:0", name: "v", desc: "Timer value [63:32]" }, ], }, // ... }
Software is expected to configure prescaler
and step
before activating the timer. These two fields need to be stable to correctly increment the timer value. If software wants to change these fields, it should de-activate the timer and then proceed.
The timer IP has 64-bit timer value registers and 64-bit compare registers. The register interface, however, is set to 32-bit data width. The CPU cannot access 64-bit data in a single request. However, when split into two reads, it is possible the timer value can increment between the two requests.
The IP doesn‘t have a latching or blocking mechanism to avoid this issue. It is the programmer’s responsibility to ensure the correct value is read. For instance, if the CPU reads 0xFFFF_FFFF
from lower 32-bit timer value (mtime
) and 0x0000_0001
from upper 32-bit timer value (mtimeh
), there is a chance that rather than having the value 0x1_FFFF_FFFF
the timer value has changed from 0x0_FFFF_FFFF
to 0x1_0000_0000
between the two reads. If there is the possibility of an interrupt between the two reads then the counter could have advanced even more.
This condition can be detected in a standard way using a third read. Figure 10.1 in the RISC-V unprivileged specification explains how to avoid this.
again: rdcycleh x3 rdcycle x2 rdcycleh x4 bne x3, x4, again
Updating mtimecmp
register also follows a similar approach to avoid a spurious interrupt during the register update. Please refer to the mtimecmp
section in the RISC-V privileged specification.
# New comparand is in a1:a0. li t0, -1 sw t0, mtimecmp # No smaller than old value. sw a1, mtimecmp+4 # No smaller than new value. sw a0, mtimecmp # New value.
There are some peculiarities when mtime
and mtimecmp
get close to the end of the 64-bit integer range. In particular, because an unsigned comparison is done between mtime
and mtimecmp
care is needed. A couple of cases are:
mtimecmp
close to 0xFFFF_FFFF_FFFF_FFFF. In this case the time-out event will be signaled when mtime
passes the comparison value, the interrupt will be raised and the source indicated in the corresponding bit of the interrupt status register. However, if there is a delay in servicing the interrupt the mtime
value could wrap to zero (and continue to increment) so the value read by the interrupt service routine will be less than the comparison value.
When the timer is setup to trigger a timeout
some number of timer ticks into the future, the computation of the comparison value mtime + timeout
may overflow. If this value is set in mtimecmp
it would make mtime
greater than mtimecmp
and immediately signal an interrupt. A possible solution is to have an intermediate interrupt by setting the mtimecmp
to 64-bit all-ones, 0xFFFF_FFFF_FFFF_FFFF
. Then the service routine for that interrupt will need to poll mtime
until it wraps (which could take up to a timer clock tick) before scheduling the required interrupt using the originally computed mtimecmp
value.
If mtime
is greater than or equal to the value of mtimecmp
, the interrupt is generated from the RV_TIMER module. If the core enables the timer interrupt in MIE
CSR, it jumps into the timer interrupt service routine. Clearing the interrupt can be done by writing 1 into the Interrupt Status register {{<regref “INTR_STATE0”>}}. The RV_TIMER module also follows RISC-V Privileged spec that requires the interrupt to be cleared by updating mtimecmp
memory-mapped CSRs. In this case both {{<regref “COMPARE_LOWER0_0”>}} and {{<regref “COMPARE_UPPER0_0”>}} can clear the interrupt source.
{{< dif_listing “sw/device/lib/dif/dif_rv_timer.h” >}}
{{< incGenFromIpDesc “../data/rv_timer.hjson” “registers” >}}