This document specifies the functionality of the pattern generator hardware IP (HWIP). This module conforms to the Comportable guideline for peripheral functionality. See that document for integration overview within the broader top-level system.
pda
) output, which is synchronous to a corresponding parallel clock signal (pcl
).The pattern generator HWIP transmits short (maximum 64 bits) time-dependent data patterns on two clock-parallel channels. Each channel consists of one clock (pcl
) and one data (pda
) line. The output channels may be activated and operated independently, or they can be started at the same time to effectively create a 4-output pattern.
This IP block does not have any direct hardware compatibility requirements.
The pattern can be started (or halted) on either channel by setting the corresponding CTRL.ENABLE
bit to 1 (or 0) for the desired channel. Once disabled, either channel can be configured independently. The channel parameters (i.e. clock divider ratio, clock polarity, pattern length, pattern data, and repetition count) can all be programmed on a per-channel basis. Enabling the pattern generator channel starts the pattern from the beginning.
Please note that writes to a channel's configuration registers have no effect while the channel is enabled. For operational simplicity, the configuration registers are only transferred into the internal finite state machines while a channel is disabled. Changes to the configuration registers only take effect once the channel has been disabled and re-enabled.
The design consists of two identical and independent finite state machines, each an instance of module pattgen_fsm
. Each FSM is essentially three nested counters, with one counter to control the clock division, another to count out the sequence bits, and a third to keep count of the number of repetitions.
Each FSM consists of
clk_io
, reset
, enable
, clk_pre_divide
, pattern
, pattern_size
, polarity
, and n_repeats
pda
and pcl
IDLE
, ACTIVE
, and END
,clk_div
,clk_int
, andbit_ctr
and repeat_ctr
.Each FSM is disabled when enable
is low. Disabling the FSM is equivalent to an FSM reset, and both operations place the FSM in the IDLE
state. While in IDLE
, the other state machine registers assume their default states: The internal counters, the clock-divide, bit_ctr
and repeat_ctr
all reset to 0, as does clk_int
.
Once the FSM is enabled, it transitions to the ACTIVE
state. The clock-divide counter clk_div
increments every cycle, except when it overflows matching the value applied to the clk_pre_divide
input. Then clk_div
resets to 0, toggling clk_int
in the process. Two overflow events result in a complete clock cycle, resulting in an internal clock frequency of: $$f_{pclx}=\frac{f_\textrm{I/O clk}}{2(\textrm{CLK_RATIO}+1)}$$
The FSM clock output, pcl
, is directly driven by clk_int
, unless the polarity
input is high, in which case pcl
is inverted from clk_int
.
The bit_ctr
counter increments on every falling edge of clk_int
, until it overflows at the pattern length based on the pattern_size
input.
In the ACTIVE
state, the FSM pda
output is driven by a multiplexer, connected to the pattern
input. The value of bit_ctr
selects the bit value from the appropriate sequence position, via this multiplexor.
Finally whenever bit_ctr
overflows and reverts to zero, the repeat_ctr
increments, and the pattern starts again. Finally repeat_ctr
overflows to zero as it reaches the input value n_repeats
. When this overflow occurs, the FSM transitions to the END
state. All counters halt, the pda
data lines reset to zero, and an interrupt event is sent out to signal completion.
The entire sequence can be restarted either by resetting or disabling and re-enabling the FSM.
The pattern generator HWIP provides two interrupt pins, done_ch0
and done_ch1
, which indicate the completion of pattern generation on the output channels. These interrupts can be enabled/disabled by setting/un-setting the corresponding bits of the INTR_ENABLE
register. To clear the interrupts, bit 1
must be written the corresponding bits of INTR_STATE
register
To start pattern generation, the register interface of the pattern generator HWIP should be properly initialized and configured.
The guide that follows provides instructions for configuring Channel 0. To configure Channel 1, use the registers with the “CH1” suffix, instead of the “CH0” registers.
To configure a single channel:
CTRL.ENABLE_CH0
.CTRL.POLARITY_CH0
, to determine the desired clock phase. For either channel, a zero in the polarity bit indicates that the channel clock line (pcl
) should start low, and the channel data line pda
transitions on every falling edge of pcl
. A one in the polarity bit inverts the pcl
clock so that it starts high and pda
transitions on the rising edge. The following waveform illustrates the effect of the POLARITY
bit. Here both channels are configured for simultaneous pattern generation, but the two channels are configured for opposite polarity.{signal: [ {name: 'CTRL.ENABLE_CH0', wave: 'lh......'}, {name: 'CTRL.POLARITY_CH0 (default: low)', wave: '0.......'}, {name: 'pcl0_tx', wave: '0.hlhlhl'}, {name: 'pda0_tx', wave: 'x3.3.3.3', data: 'DATA[0] DATA[1] DATA[2]'}, {name: 'CTRL.POLARITY_CH1 (high)', wave: '1.......'}, {name: 'pcl1_tx', wave: '1.lhlhlh'}, {name: 'pda1_tx', wave: 'x5.5.5.5', data: 'DATA[0] DATA[1] DATA[2]'}, ], head: {text: 'Effect of the Polarity Registers',tick:0}}
SIZE.LEN_CH0
. Note that since the allowed seed length ranges from 1-64, the value of this field should be one less than the pattern length. For example, to generate an 16-bit pattern, a value of 15 should be written to the field SIZE.LEN_CH0
.DATA_CH0_0
and DATA_CH0_1
. The first 32 bits to be transmitted, are programmed in the lower half of the multi-register (i.e. DATA_CH0_0
), and the latter 32 bits are programmed in the upper half of the multi-register (i.e. DATA_CH0_1
).PREDIV_CH0.CLK_RATIO
. The resulting clock frequency will be slower than the input I/O clock by a ratio of 2×(CLK_RATIO+1): $$f_{pclx}=\frac{f_\textrm{I/O clk}}{2(\textrm{CLK_RATIO}+1)}$$SIZE.REPS_CH0
. Note that since the allowed number of pattern repetitions ranges from 1-1024, the value of this field should be one less than the desired repetition count. For example, to repeat a pattern 30, a value of 29 should written to the field SIZE.REPS_CH0
.CTRL.ENABLE_CH0
. To start both channel patterns at the same time, configure both channels then simultaneously assert both the CTRL.ENABLE_CH0
and CTRL.ENABLE_CH1
bits in the same register access.